Use Our Cloud For Your Data And Services – Securely And

Browse technical resources about telecom shelters, power systems, fiber infrastructure, and broadcast networks.

  • High-efficiency low-noise UPS systems for use in data center IDC computer rooms

    High-efficiency low-noise UPS systems for use in data center IDC computer rooms

    High Efficiency UPS Systems deliver double-conversion protection, low THD, high power factor, intelligent battery management for data centers, ensuring clean power, reduced losses, redundancy, advanced SNMP monitoring, and remote alerts. Uninterruptible Power Supply (UPS) systems ensure power is available without interruption during outages, fluctuations, or other power disturbances. They typically use batteries as an emergency power source that may last for a few seconds to tens of minutes – just enough time for either emergency generators to come online, or for computing equipment to be. These systems incorporate the latest power protection technology to create a new level of reliability and efficiency. As technology advances, so does the demand for uninterrupted power.


  • Why do IDC data centers still use multimode fiber optic cables

    Why do IDC data centers still use multimode fiber optic cables

    Why is multimode fiber still common in data centers? Despite the rise of single mode, multimode fiber remains the default choice in many data centers due to its affordability and ease of use. At first glance, this assumption appears logical. 1 What roles do single mode and multimode. At the core of data center connectivity are fiber optic cables, which are thin strands of plastic that transmit data using light signals or wavelengths, offering unparalleled speed and efficiency. This is made possible by its relatively large core diameter, typically 50 or 62. 5 microns, compared to the ~9-micron core in single-mode fiber. Traditional copper cabling is no longer sufficient to meet these evolving requirements. Choosing the right fiber is critical for ensuring a data center can meet the.


  • Customized Data Center Cold Aisle

    Customized Data Center Cold Aisle

    Design, manufacture and install of bespoke aisle containment systems for use in retrofit, new build and hyperscale projects. Aisle containment is a recognised solution to aid the cooling of high-density server installations within Data Centres and Enterprise IT rooms. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. Essentially creating a room within the aisle, the system helps keep hot and cold air separated to make existing air conditioning systems in data center and edge-of-network. Our aisle containment systems are designed to optimize energy use and enhance airflow management in data centers, both new and existing.


  • Intelligent QSFP-DD Optical Module for Data Center Interconnection

    Intelligent QSFP-DD Optical Module for Data Center Interconnection

    QSFP-DD is a new module and cage/connector system similar to current QSFP, but with an additional row of contacts providing for an eight lane electrical interface. It is being developed by the QSFP-DD MSA as a key part of the industry's effort to enable high-speed solutions. This guide explores key technical features for GPU clusters, examines spine-leaf architectures for distributed AI applications, and evaluates whether QSFP-DD or OSFP is better suited for future AI data centers. Planning AI cluster networking? Explore our QSFP-DD transceiver solutions for high-speed. Cisco QSFP-DD and OSFP 800G ZR/ZR+ digital coherent optics modules enable 800G traffic over amplified Dense Wavelength-Division Multiplexing (DWDM) links up to 120 km for 800ZR and over 1000 km for 800G ZR+. Customers can upgrade their box in advance of new cables. QSFP DD, short for Quad Small Form-factor Pluggable Double Density, is a high-density optical transceiver form factor designed for high-speed networking applications. The QSFP-DD specification, maintained by the QSFP-DD.

    [PDF Version]
  • Construction of China Mobile Internet Data Center

    Construction of China Mobile Internet Data Center

    The China Mobile Yangtze River Delta (Suzhou) Fenhu Intelligent Computing Center is a computing hub of the national integrated big-data center system. With a total investment of 6 billion yuan, it is planned to build 9,990 racks with a total computing power of 15,000 PFLOPS. The main machine building of China Mobile Limited (China Mobile)'s Free Trade Port (FTP) Internet Data Center (IDC). China Mobile's Harbin New-type Green Data Center General Contracting project embraced a number of technical innovations in the field of Data Center construction, achieving a great breakthrough in theories, technologies and methodologies. Referred to by the company as a "computing center", it is kitted out 4,000 artificial intelligence (AI) accelerator cards, reports China Daily. China Mobile claims 33 percent of the AI chips are domestically developed, and that it has a. The facility in Xi'an, Northwest China, was divided into 232 modules, with the equipment prefabricated and preinstalled in a factory.

    [PDF Version]
  • Case Study of Hot Aisle Construction in Iranian Data Center

    Case Study of Hot Aisle Construction in Iranian Data Center

    A new type of ducted hot aisle containment system for racks cooling of data center has been proposed and put into practice gradually. However, the related academic research has not been carried out, esp.


  • Data Center PDU Classification

    Data Center PDU Classification

    Data center PDUs distribute power from UPS or utility-backed systems to rack equipment. This guide explains PDU types, key features, deployment styles, and how to choose the right unit for uptime, monitoring, and power efficiency. The power distribution unit (PDU) market is projected to grow exponentially alongside the expansion of the global data center market from 2026 through 2030. Driven by the growth of hyperscale cloud, edge computing, and AI workloads, rack-level power distribution has become a strategic priority. As Data Centers evolve to handle increasing power densities driven by AI, cloud computing, and high-performance applications, PDUs have advanced from simple power strips to intelligent systems offe ing Monitoring, Remote Management, and. A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within a data center.

    [PDF Version]
  • Data Center Home Network Rack Installation

    Data Center Home Network Rack Installation

    This guide walks you through the full process, from choosing the right rack to installing hardware, power, cooling, and network components. Your rack selection determines how much equipment you can mount today and how easily you can expand later. A well-designed rack improves airflow, cable routing, and serviceability while keeping your equipment secure. Below is a practical roadmap—hardware selection, layout, cable management, power, cooling, noise, and security—with field-tested tips to make everything reliable and easy to maintain. Start with an. Today's video is the final video in a 3 part series where I cover how to plan, implement and install a new home network. If you are building a home, make sure you check out this entire series to learn my pro tricks for planning your low voltage network cabling in your new construction home. more. Written by Don Schultz, trueCABLE Senior Technical Advisor, Fluke Networks Copper/Fiber CCTT, BICSI INSTC, INSTF Certified All your permanent networking cable has been installed. Essentially, that means the “server” rack.

    [PDF Version]
  • Attenuation data in fiber optic communication

    Attenuation data in fiber optic communication

    Attenuation in fiber optics is the gradual loss of light signal strength as it travels through a fiber cable. But what happens when that light fades? Optical Signal Attenuation is the single greatest factor limiting the distance and performance of your network. This loss happens due to a variety of factors. It is measured using decibels (dB). Understanding this phenomenon is crucial for anyone involved in network engineering. Losses can be introduced by various means such as intrinsic material absorption, scattering, bending, connector loss and more.


Telecom & Site Infrastructure Insights